EPSON Stylus PHOTO 895/785EPX Revision A
Appendix Connector Summary 153
Note :
*1 Adjusted at factory.
*2 Initialized after performed panel initialization of EEPROM.
*3 Initialized after performed panel initialization of the ink overflow.
39H 1stDot Position
Adjustment
-72<=n<=+72 (by 1/2880inch)
00H (*1)
3AH CL2 Counter KK 00H 03H
3BH Total Timer CL
Counter
00H 00H
3CH Printer For CSIC
00H
89H:
Standard
09H:
Japan
3DH CSIC1_InkName1;
00H 00H
3EH CSIC2_InkName1;
3FH Head Actuator Rank
ID for VhN
+1<=n<=+32
00H (*1)
40H Head Actuator Rank
ID for VhM
+1<=n<=+37
00H (*1)
41H Head Actuator Rank
ID for VhL
+1<=n<=+34
00H (*1)
42H Head Actuator Rank
ID for VhU
+1<=n<=+40
00H (*1)
43H Head Actuator Rank
ID for VhM2
+1<=n<=+34
00H (*1)
44H Head Actuator Rank
ID for VhB
+1<=n<=+34
00H (*1)
45H Head Actuator Rank
ID for AR
0<=n<=+6
00H (*1)
46H Head Actuator Rank
ID for IwB
+30<=n<=+70
00H (*1)
47H Head Actuator Rank
ID for IwC
+30<=n<=+70
00H (*1)
48H Head Actuator Rank
ID for IwM
+30<=n<=+70
00H (*1)
Table 7-14. EEPROM Address Map
Address Explanation Setting
QPIT
setting
Factory
setting
49H Head Actuator Rank
ID for IwY
+30<=n<=+70
00H (*1)
4AH Head Actuator Rank
ID for IwLC
+30<=n<=+70
00H (*1)
4BH Head Actuator Rank
ID for IwLM
+30<=n<=+70
00H (*1)
4CH
|
5DH
USB ID 00H
|
00H
(*1)
|
(*1)
5EH Market ID 0: World (Euro, Asia)
1: Japan
2: Custom
3: World (US)
00H 03H
5FH Reserved
60H
|
7DH
Model Name 00H
|
00H
-
|
-
7EH Password 55H -
7FH Password 33H -
Table 7-14. EEPROM Address Map
Address Explanation Setting
QPIT
setting
Factory
setting

Table of Contents