4.2.6.3 PF Encoder Sensor
1. Remove the L SIDE COVER ASSY. See Section 4.2.3.5 on page 224.
2. Remove the three screws that secure the PF ENC COVER B. See Figure 4-88.
Three C.B.S. M3 x 8 screws
3. Release the three tabs that secure the PF ENC COVER B and remove it. See
Figure 4-88.
4. Remove the connector from the PF Encoder Sensor. See Figure 4-89.
5. Remove the two screws that secure the PF Encoder Sensor and remove it. See
Figure 4-89.
Two C.P.P. M2.6 x 6 screws
Figure 4-88. Removing the PF ENC COVER B
Figure 4-89. Removing the PF Encoder Sensor
C A U T I O N
When removing the SCALE, PF, be careful not to deform or
damage it. See Figure 4-89.
C A U T I O N
When removing the PF Encoder Sensor, be careful not to bend the
capacitor on the sensor. See Figure 4-89.
C.B.P. M3x8
Tabs
Left Side of the Printer
PF ENC COVER B
PF Encoder
Sensor
SCALE, PF
Capacitor
Connector