VT6L Maintenance 12. Joint #4
VT series Maintenance Manual Rev.2 99
the Manipulator.
Reference: VT series Manual VT6L Manipulator 6.5 LED
Manipulator for the first time after replacing the motor unit, the
motor unit firmware is automatically updated.
DO NOT turn OFF the Manipulator
When you connect a motor unit connected to another axis, an error 5009 or 9709 will
occur. To clear the error, enter the following command in [Command Window] and
execute it.
Joint #1: > MUIDReset 1
Joint #2: > MUIDReset 2
Joint #3: > MUIDReset 3
Joint #4: > MUIDReset 4
Joint #5: > MUIDReset 5
Joint #6: > MUIDReset 6
Reboot the Controller.
Reference: 19. Calibration