VT6L Maintenance 10. Joint #2
VT series Maintenance Manual Rev.2 81
(11)
Turn ON the
Manipulator.
Reference: VT series Manual VT6L Manipulator 6.5 LED
When starting the Manipulator for the first time after replacing the motor unit, the motor
unit firmware is automatically updated. DO NOT turn OFF the Manipulator until it
starts.
When you connect a motor unit connected to another axis, an error 5009 or 9709 will
occur. To clear the error, enter the following command in [Command Window] and
execute it.
Joint #1: > MUIDReset 1
Joint #2: > MUIDReset 2
Joint #3: > MUIDReset 3
Joint #4: > MUIDReset 4
Joint #5: > MUIDReset 5
Joint #6: > MUIDReset 6
Reboot the Controller.
(12)
Calibrate the Joint #2.
Reference: 19. Calibration
NOTE