2011/03/02
Revision: 1 Page: 81
7.5 Cleaning time information
Structure
Item Byte (Hex) Value (Hex)
Header 1 0C
Parameter counter 1 02
Parameter 2 Cleaning time information
The parameter <cleaning time information> is two bytes Binary codes that indicate cleaning time or ink filling time.
The unit is second. (This time is total time not passage time or remains time.)
This parameter is added only when status code ST = 07H.
7.6 Replace cartridge information
Structure
Item Byte (Hex) Value (Hex)
Header 1 0E
Parameter counter 1 01
Parameter 1 Replace cartridge information
The parameter <change cartridge information> is one byte Binary code that indicates the information about ink cartridge. 00
means that any ink cartridge is changed.
Bit0: The 1
st
data of 0F field
Bit1: The 2
nd
data of 0F field
Bit2: The 3
rd
data of 0F field
Bit3: The 4
th
data of 0F field
Bit4: The 5
th
data of 0F field
Bit5: The 6
th
data of 0F field
If the plural ink cartridges are changed at the same time, the both bits set 1.