2011/03/02 
Revision: 1            Page: 83 
 
 
 
7.9 Cancel code 
 
Structure 
Item  Byte (Hex)  Value (Hex) 
Header  1  13h 
Parameter counter  1  01 
Parameter  1  Cancel request 
 
The parameter <cancel code> is one byte Binary code that indicates the cancel request. 
Cancel request  Code 
No request  01 
The status during received cancel command and initialize the printer  A1 
Request  81 
 
7.10 Job name Information 
 
Structure 
Item  Byte (Hex)  Value (Hex) 
Header  1  19 
Parameter counter  1  n (Max 37) 
Parameter  Max 37  Job name information 
 
The parameter <Job name information> is n bytes Binary codes. 
It indicates the m1 to m5 parameter and Job name specified by JH command.   
 
If the JH command is not send of printing job, it replies “unknown”. 
Item  Byte (Hex)  Value (Hex) 
Header  1  19 
Parameter counter  1  0C 
Parameter  0C  0000000000 “unknown”