EasyManua.ls Logo

Ercogener GenPro 425e - Environmental Characteristics

Ercogener GenPro 425e
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EG_GenPro425e_1103_UG_001_UK.docx
Page 15 / 51
Descriptions and non-contractual illustrations in this document are given as an indication only.
ercogener reserves the right to make any modifications.
Dct_427_02
2.5 Environmental characteristics
To ensure a correct operation of the modem, the specific limits described in the table below must be
respected.
Table 5 : Environmental characteristics
If the battery option is installed, the environmental conditions are different. See table below.
Operating temperature range
-20°C to +50°C
Battery charge functional range
0 °C to +45 °C
Storage temperature range
1 year of storage with -20°C to + 35°C
3 months of storage with -20°C to + 45°C
1 month of storage with -20°C to + 60°C
Relative humidity
65 ±20%
Below 0°C and above 45 °C inside the device, the protection of the battery management
triggers. The battery will not charge.
Operating temperature range
-20 °C to +60 °C
Storage temperature range
-40 °C to +85 °C
Operating humidity without condensation
HR < 70% @ +55°C