7 GENERAL FUNCTIONS
0459 287 601
- 24 -
© ESAB AB 2020
7 GENERAL FUNCTIONS
7.1 Remote control unit
Control panel's behaviour on connection of the remote control unit
Machines with intergral control panels should have program version 1.21 or higher, in order
for the remote control to function correctly.
• The display freezes in the menu showing when the remote control unit is connected.
Measurement and setting values are updated, but only displayed in those menus in
which the values can be shown.
• If a fault code symbol is displayed, it cannot be removed until the remote control has
been disconnected.
• With 10-program remote control units, it is possible to switch between memory
positions 1, 2, 3, 4, 5, 6, 7, 8, 9 and 10. If memory position 2 is empty, the values from
position 1 are retained. For further information, see the “MEMORY MANAGEMENT”
chapter.
7.2 Language
The text on the display panel is available in the following languages: Swedish, Danish,
Norwegian, Finnish, English, German, Dutch, French, Spanish (Castilian), Italian,
Portuguese, Polish, Czech, Hungarian, Turkish and US English.
7.3 Dimensions
Dimensions can be set to Metric or Inch. Default is Metric.
7.4 Panel enable
When a remote control unit is connected it is possible to set current or voltage and wire feed
speed by the control panel or the remote control unit.
NOTE!
This function must be activated before the remote control unit is connected.
• Activation of panel enable is performed in the CONFIGURE MENU.
Default is ON.
7.5 Auto save
If a welding data setting is recalled from the welding data memory and the settings are
adjusted, the changed settings will automatic be saved when a new welding data setting is
recalled from the memory.
• Activation of auto save is performed in the CONFIGURE MENU.
Default is OFF.
7.6 Limits
This function facilitates the assurance of a good welding quality by setting max. and min.
values for wirefeed / current or voltage. The limits can be saved in the first 5 memory
positions of the welding data memory.
• Activation of limits is performed in the CONFIGURE MENU.