6 CONTROL PANEL
0463 930 001
- 22 -
© ESAB AB 2023
Indicator Description
MIG/MAG SPOT
Spot welding is used when you want to spot weld thin plates together.
NOTE!
It is not possible to shorten the welding time by releasing the
trigger switch.
MMA
MMA welding may also be referred to as welding with coated
electrodes. Striking the arc melts the electrode, and its coating forms
protective slag.
Measured voltage
Measured value in the display for welding voltage V is an average
numerical value which is calculated during the welding excluding the
weld termination.
Trim
Trim is the process of adjusting the parameter within an acceptable
range.
This function is applicable only in MIG/MAG Synergic.
Measured amperage
Measured value in the display for welding current A is an average
numerical value which is calculated during the weld excluding the weld
termination.
Wire feed speed
Measured value in the display for wire feed speed is an average
numerical value which is calculated during the weld excluding the weld
termination.
Thickness
Selected thickness in the display for the welding workpiece.
This function is applicable only in MIG/MAG Synergic.
Time
Selected time in the display for the spot and rest time in seconds.
This function is applicable only in MIG/MAG Spot.