RELAY SETTINGS
This programming allows you to configure the relay output, available in
the R2R and 3G versions, either as bistable or monostable (by defining
the duration of the impulse in seconds). This programming only applies
when the relay is not used to signal the external power supply and/or
GSM/UMTS network failure.
Factory default: monostable (1s).
Note: the relay can command loads with up to 1A to 24V
absorption.
(value)
(confirm)
Lift the handset and dial: **93*.
Enter:
00 bistable output replay (the relay is activated or
deactivated by the code digited by the user during
operation);
01
~99 monostable output relay (the relay executes an impulse
of the time length preset in seconds).
Dial # to confirm.
After the confirmation tone hang up or carry on with other
programmings.