ProNet Plus Series AC Servo User's Manual
- 125 -
5.2.1 Alarm Traceback Data Display
The alarm traceback display can display up to 10 previously occurred alarms.The alarm is displayed on Fn000, which is
stored in the alarm traceback data.
Follow the procedures below to confirm alarms which have been generated.
1. Press the MODE key to select the utility function mode.
2. Press the INC or DEC key to select the function number of alarm trace back data display.
3. Press the ENTER key once, the latest alarm data is displayed.
Alarm Sequence NumberAlarm Code
4.Press the INC or DEC key to display other recent alarms that have occurred.
5. Press the ENTER key, the display will return to Fn000.
Note: Hold the ENTER key for one second with alarm code displaying, all the alarm traceback datas will be cleared.
5.2.2 Parameter Settings Initialization
Follow the procedures below to execute the parameter settings initialization.
1.Press the MODE key to select the utility function mode.
2. Press the INC or DEC key to select the function number of parameter settings initialization.
3.Press the ENTER key to enter into parameter settings mode.
4.Hold the ENTER key for one second, the parameters will be initialized.
5. Release the ENTER key to ruturn to the utility function mode display Fn001.