ProNet Plus Series AC Servo User's Manual
The display methods of Un009, Un011 and Un013 are as follows:
(1) Three pages are used for display. The first page is showing low 4 bit. The second page is showing medium4 bit.The
third page is showing high 4 bit.
(2) The 5th digital tubeis responsible for displaying the low4 bit, the medium 4 bit or the high 3 bit. The bottom line of the
flash display shows the low 4 bit.The middle line of the flash display shows the middle 4 bit. The top line of the flash
display shows the high 3 bit.
(3) When the parameter value is negative, the decimal point of the 5th digital tube will be lit. No matter which page it is
on. And the fourth digital tube of the third page shows a minus sign.
(4) Switching low 4 bit, medium 4 bit and high 3 bit pages is done by the UP and DOWN buttons.
-121 4748 3648 is shown as follows:
low 4 bit medium 4 bit high 3 bit
121 4748 3647 is shown as follows:
low 4 bit medium 4 bit high 3 bit
5.2Operation in Utility Function Mode
In utility function mode, the panel operator can be used to run and adjust the servo drive and servomotor.
The following table shows the parameters in the utility function mode.
Alarm traceback data display
Parameter setting initialization
Automatic adjustment of speed reference offset
Manual adjustment of speed reference offset
Automatic adjustment of servomotor current detection