EasyManua.ls Logo

Estun ProNet-30D - Page 214

Estun ProNet-30D
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ProNet Plus Series AC Servo User's Manual
- 212 -
Alarm
Display
Alarm
Output
Alarm Name
Meaning
A25
Motor power line U overcurrent
Mechanical stuck or motor power line U phase sequence is
wrong.
A26
Motor power line V overcurrent
Mechanical stuck or motor power line V phase sequence is
wrong.
A27
Motor power line W overcurrent
Mechanical stuck or motor power line W phase sequence
is wrong.
A28
Nikon encoder temperatur is too
high
Nikon Encode internal Temperature (unit: )
A38
Encoder LED error
Encoder is faulty.
A39
Encoder EEPROM error
Encoder is faulty.
A41
Reserved
Reserved
A42
Servomotor type error
The parameter setting of servo drive does not match the
servomotor.
A43
Servo drive type error
The parameter setting of servo drive does not match the
servomotor.
A44
Reserved
Reserved
A45
Absolute encoder multiturn
information error
Absolute encoder multiturn information is faulty.
A46
Absolute encoder multiturn
information overflow
Absolute encoder multiturn information overflow.
A47
Battery voltage below 2.5V
Absolute encoder multiturn information is lost.
A48
Battery voltage below 3.1V
Battery voltage is too low.
A49
The position of the encoder was
changed.
Not connect the battery, the battery voltage is low, or the
encoder had been damaged.
A50
Serial encoder communication
overtime
Encoder disconnected; encoder signal disturbed; encoder
error or encoder decoding circuit error.
A51
Absolute encoder overspeed alarm
detected
Absolute encoder multiturn information may be faulty.
Error reasons:
1.The battery is not connected or the battery voltage is
insufficient.
2.The power supply to servo drive is not turned ON when
the battery voltage is normal, or the servomotor running
acceleration is too high due to external reason.
A52
Absolute state of serial encoder
error
Encoder or the encoder decoding circuit is faulty.
A53
Serial encoder calcaution error
Encoder or the encoder decoding circuit is faulty.
A54
Parity bit or end bit in serial encoder
control domain error
Encoder signal is disturbed or the encoder decoding circuit
is faulty.
A55
Serial encoder communication data
checking error
Encoder signal is disturbed or the encoder decoding circuit
is faulty.