Show Control 541
OSC Method Arguments Examples/Comments
/eos/ping=”abcde”
/eos/ping=”abcde”,4
Ping response - see Implicit OSC Output (on page558) for more information
/eos/out/ping Same number of arguments that were sent
/eos/out/ping
/eos/out/ping=”abcde”
/eos/out/ping/=”abcde”,4
Supported OSC Input
All OSC commands must begin with “/eos/...” or “/eos/user/<number>/...”.
Note: All of the command examples given can also use the “/eos/user/<number>/...”. vari-
ant.
Chan
Channel commands allow you to select Eos channels. You can directly change the channel level
information in the same command, or use this as a selection tool for other controls like Absolute con-
trols (see below).
OSC Method Arguments Examples/Comments
Select achannel
/eos/chan number for channel to select /eos/chan=1
/eos/chan/<number> number for channel level
/eos/chan/1=75 (useful for mapping to an
OSC slider)
Set channelintensitylevels
/eos/chan/<number>/out
number for button edge: 1.0=down, 0.0=up
(optional)
/eos/chan/1/out
/eos/chan/<number>/home
number for button edge: 1.0=down, 0.0=up
(optional)
/eos/chan/1/home
/eos/chan/<number>/remdim
number for button edge: 1.0=down, 0.0=up
(optional)
/eos/chan/1/remdim
/eos/chan/<number>/level
number for button edge: 1.0=down, 0.0=up
(optional)
/eos/chan/1/level
/eos/chan/<number>/full
number for button edge: 1.0=down, 0.0=up
(optional)
/eos/chan/1/full
/eos/chan/<number>/min
number for button edge: 1.0=down, 0.0=up
(optional)
/eos/chan/1/min
/eos/chan/<number>/max
number for button edge: 1.0=down, 0.0=up
(optional)
/eos/chan/1/max
/eos/chan/<number>/+%
number for button edge: 1.0=down, 0.0=up
(optional)
/eos/chan/1/+%
/eos/chan/<number>/-%
number for button edge: 1.0=down, 0.0=up
/eos/chan/1/-%