626 Ion Classic User Manual
OSC Show Control Events
Show control events are fired as the console executes the corresponding action, much like
MIDI Show Control output events.
OSCMethod Arguments/Comments
/eos/out/event/cue/<cue list number>/<cue
number>/fire
/eos/out/event/cue/<cue list number>/<cue
number>/stop
/eos/out/event/sub/<sub number>
Integer argument: 0=Bump Off,
1=Bump On
/eos/out/event/macro/<macro number>
/eos/out/event/relay/<relay number>/<group
number>
Integer argument: 0=On, 1=Off
/eos/out/event Used for Time Code learn
OSCShow File Information
OSCMethod Arguments/Comments
/eos/out/show/name String argument with show title
/eos/out/event/show/saved String argument with file path
/eos/out/event/show/loaded String argument with file path
/eos/out/event/show/cleared
OSCMiscellaneous Console Events
OSCMethod Arguments/Comments
/eos/out/event/state Integer argument: 0=Blind, 1=Live
Note:
When Eos receives the command /eos/ping it will reply with
/eos/out/ping. You may optionally add any number of arguments and Eos will reply
with the same arguments. This may be useful for testing latency.