MOTOR CARBON BRUSHES CHECK
CHECK AND REMOVE THE MOTOR CARBON BRUSHES ONE AT A TIME SO AS NOT TO INVERT THEM. THE
MOTOR CARBON BRUSHES SETTLE AND WEAR DIFFERENTLY THE ONE FROM THE OTHER,
CONSEQUENTLY IF THESE ARE INSPECTED AND PUT BACK ON AGAIN BECAUSE THEY ARE NOT FULLY
WORN, THEY MUST BE REFITTED IN THE SAME POSITION.
VACUUM MOTOR
Check the carbon brushes (2 in all) and replace them if they are shorter than 6 mm.
BRUSHES MOTOR
Check the carbon brushes (4 for each motor) and replace them if they are shorter than 4 mm.
MOTORWHEEL
Check the carbon brushes (4 in all) and replace them if they are shorter than 7 mm.
Check also the motor oil level in the motorwheel.
MACHINE
Check that the battery clamps are not loosen or oxidized
Check the batteries fluid level
Check the cover gasket
Check the vacuum motor filter
Check the brake
Check, and if necessary replace, the fuses
Check the brushes and the components of the brush plate
Check, and if necessary rotate or replace, the squeegee blades
Check the adjusting/closing detergent solution tap
Check the detergent solution filter (located just before the pump)
Check the pump, the solenoid valve and the fitting outgoing from the pump
Check that the vacuum pipe on the squeegee and the drainpipes of the solution and recovery tanks are
not broken or clogged
Proceed with the cleaning of the ECO system device and its components
Check the bearings of the wheels
Check the actuators of the squeegee and the brush plate (anyway if actuators have problems, they will be
detected by the control board)
Lubricate the squeegee pivot pin
Test the machine in all its operating functions