EasyManua.ls Logo

Everidge Thermalrite - Page 81

Everidge Thermalrite
93 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ThermalRite Blast Chiller Easy Touch Screen Manual
81
Rev02132016
Parameter
Description
Reach
In
120V
Reach
In
230V
Roll In
DWA
load tolerance on relays [%]
20
20
20
STO
max storage time without hot gas
defrost [hours]
48
48
48
DFS
difference between core probe and
cabinet probe to detect core probe
inserted [°C/°F]
18
18
18
STE
sterilization cycle duration [sec]
300
300
300
PRH
heating core probe cycle duration
[sec]
60
60
60
VOF
mains voltage sensor offset [num]
77
77
77
PTE
not used
20
20
20
PTI
not used
12
12
12
MRT
max recharging time of battery
[hours]
20
20
20
FCD
max first recharging time of battery
[hours]
12
12
12
BTD
max duration of battery test [sec]
3
3
3
TBT
consecutive battery test interval
time [min]
5
5
5
NMT
not used
250
250
250
VRS
start battery charging threshold
[V/10]
11,1
11,1
11,1
VRE
end battery charging threshold
[V/10]
11,3
11,3
11,3
VRT
battery voltage at ending charging
for max duration [V/10]
9,8
9,8
9,8
VBR
minimum battery voltage for
disabling battery [V/10]
8,6
8,6
8,6
VAD
battery voltage threshold to show
"no battery" message [V/10]
3,3
3,3
3,3
VPD
battery voltage threshold to detect
presence of battery [V/10]
5
5
5
TBK
delay time before safety turn off of
battery circuit [sec]
60
60
60
BOF
battery voltage offset [V/10]
0
0
0
MST
max air temperature during
thawing [°C/°F]
50
50
50
OFH
not used
3
3
3
PAT
air temperature in pre-thawing
cycle [°C/°F]
43
43
43
PFT
evaporator fan speed in pre-
thawing cycle [%]
10
10
10
PAC
air temperature in pre-soft cooking
cycle [°C/°F]
43
43
43
PFC
evaporator fan speed in pre-soft
cooking cycle [%]
6
6
6
HHL
lower differential heating action
[°C/°F]
5
5
5
HHH
upper differential heating action
[°C/°F]
5
5
5
MRV
nominal mains voltage [V]
115
230
230
PRF
evaporator fan declared power [W]
100
100
100