Design and function
Remote control
82
099-004854-EW501
19.02.2014
5.13 Remote control
NOTE
Insert the remote control control cable into the 19-pole connection socket for remote
control connection and lock.
5.13.1 Manual remote control RT1 19POL
Functions
Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current on the welding machine.
5.13.2 RTG1 19POL manual remote control
Functions
Infinite setting of the welding current (0% to 100%) depending on the main current
preselected at the welding machine
5.13.3 Manual remote control RTP1 19POL
Functions
TIG/MMA
Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current on the welding machine.
Pulse/spot/normal
Pulse, spot and break times are infinitely adjustable.
5.13.4 Manual remote control RTP2 19POL
Functions
TIG/MMA.
Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current on the welding machine.
Pulse/spot/normal
Frequency and spot times infinitely adjustable.
Coarse adjustment of the cycle frequency.
Pulse/pause ratio (balance) adjustable from 10% to 90%.
5.13.5 RTP3 spotArc 19POL manual remote control
Functions
TIG / MMA.
Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current on the welding machine.
Pulse / SpotArc spots / normal
Frequency and spot time infinitely adjustable.
Coarse adjustment of the pulse frequency.
Pulse/pause ratio (balance) adjustable from 10% to 90%.
5.13.6 Manual remote control RT AC 1 19POL
Functions
Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current on the welding machine.
AC frequency of welding current infinitely adjustable.
AC balance (positive/negative half-wave ratio) can be set from +15% to -15%.