EasyManua.ls Logo

EWM Tetrix 350 - General Maintenance and Care Schedule; General Maintenance and Care; Maintenance Work and Intervals; Daily Maintenance Tasks

EWM Tetrix 350
115 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance, care and disposal
General
099-004854-EW501
19.02.2014
99
6 Maintenance, care and disposal
DANGER
Risk of injury from electric shock!
Cleaning machines that are not disconnected from the mains can lead to serious
injuries!
Disconnect the machine completely from the mains.
Remove the mains plug!
Wait for 4 minutes until the capacitors have discharged!
6.1 General
When used in the specified environmental conditions and under normal operating conditions, this
machine is largely maintenance-free and requires a minimum of care.
There are some points, which should be observed, to guarantee fault-free operation of your welding
machine. Among these are regular cleaning and checking as described below, depending on the pollution
level of the environment and the length of time the unit is in use.
6.2 Maintenance work, intervals
6.2.1 Daily maintenance tasks
6.2.1.1 Visual inspection
Mains supply lead and its strain relief
Other, general condition
6.2.1.2 Functional test
Operating, message, safety and adjustment devices (Functional test)
Welding current cables (check that they are fitted correctly and secured)
Gas tubes and their switching equipment (solenoid valve)
Gas cylinder securing elements
6.2.2 Monthly maintenance tasks
6.2.2.1 Visual inspection
Casing damage (front, rear and side walls)
Wheels and their securing elements
Transport elements (strap, lifting lugs, handle)
6.2.2.2 Functional test
Selector switches, command devices, emergency stop devices, voltage reducing devices, message
and control lamps
6.2.3 Annual test (inspection and testing during operation)
NOTE
The welding machine may only be tested by competent, capable personsl.
A capable person is one who, because of his training, knowledge and experience, is
able to recognise the dangers that can occur while testing welding power sources as
well as possible subsequent damage and who is able to implement the required safety
procedures.
For further information, please see the accompanying supplementary sheets "Machine
and Company Data, Maintenance and Testing, Warranty"!
A periodic test according to IEC 60974-4 "Periodic inspection and test" has to be carried out. In addition
to the regulations on testing given here, the relevant local laws and regulations must also be observed.