Loading...
Commissioning
Shielding gas supply
Item No.: 099-004934-EWM01 59
6.9 Shielding gas supply
6.9.1 Connecting the shielding gas supply
NOTE
With compact machines, the shielding gas connection is made on the machine itself;
with decompact machines, on the intermediate tube package of the wire feed (see
"Intermediate tube package connection").
Figure 6-5
Item Symbol Description 0
1
G¼” connecting nipple
Shielding gas connection on the pressure reducer
2 Safety chain
3 Cylinder bracket
4 Cylinder valve
5 Output side of the pressure reducer
6 Pressure reducer
7 Shielding gas cylinder
Before connecting the pressure reducer to the gas cylinder, open the cylinder valve briefly to blow out
any dirt.
Place the shielding gas cylinder into the relevant cylinder bracket.
Secure the shielding gas cylinder using a securing chain.
CAUTION
Faults in the shielding gas supply.
An unhindered shielding gas supply from the shielding gas cylinder to the welding torch
is a fundamental requirement for optimum welding results. In addition, a blocked
shielding gas supply may result in the welding torch being destroyed.
Always re-fit the yellow protective cap when not using the shielding gas connection.
All shielding gas connections must be gas tight.
Tighten gas hose on pressure reducer to be gas tight.

Table of Contents