5.8.5 Espresso group enabling/disabling
The next screen enables the Express group. This setting must be set to “enabled”, as to allow the
express group to work. With buttons “+” and “-“ we change between “enabled” and “disabled”;
with “enter” we accept the selected language, and proceed to the next adjustment.
5.8.6 Grounds counter
We will now adjust the “Grounds program”. This is a setting that enables a counter that takes care
of not overflowing the grounds container. It should be adjusted to 90 when using the standard inner
container of the machine. When the machine has brewed that number of services involving
espresso, it will prevent any more brewing of beverages involving espresso until the coffee grounds
tray is emptied.
If we are using the cabinet for the machine, we have to set the Grounds program to 0. This will turn
off the counter and allow uncounted services to be brewed.
With buttons “+” and “-“ we adjust this setting; with “enter” we accept the value, and proceed to the
next adjustment.
Note: As to empty the Grounds container once the error “empty grounds container”, open the door
of the machine and remove and empty the grounds container always with the machine connected
(on), otherwise, the machine cannot detect that the container was removed, and will not reset the
counter.
5.8.7 Pre-infusion
Next parameter is the pre-infusion setting: This setting allows a little pause at the beginning of the
erogation of the espresso (a little pause in the pumping). This lets the necessary time to the coffee as
to reach the right moistureness allowing to get the best quality out of it. Disabling this function will
save a little of time; but quality of erogated coffee will be affected. With buttons “+” and “-“ we
change between “enabled” and “disabled”; with “enter” we accept the selected language, and
proceed to the next adjustment.
5.8.8 Pre-grinding / extra speed
his setting enables the pre-grinding function; which saves some erogation time, by having always
ready the grinded coffee dose for the next espresso. This means that the machine grinds the coffee
after erogating the espressos. So always is ready to begin erogating the next one. With buttons “+”
and “-“ we change between “enabled” and “disabled”; with “enter” we accept the selected language,
and proceed to the next adjustment.
Express Group
Disabled
Enter
Express Group
Enabled
Canc
+
-
Enter
Grounds program
#
Enter
Enter
Canc
Preinfusion
DISABLED
Preinfusion
ENABLED
Canc
+
-
Enter
Enter
Extra Speed
Disabled
Extra Speed
Enabled
Canc
+
-
Enter
Enter
#=0 Counter disabled
#=90 Standard Capacity of the Grounds Container