EasyManua.ls Logo

FAAC 746 E R Z20 - Connections; Motor; Flashing Light; Magnetic Encoder

FAAC 746 E R Z20
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
35
746 E R 23 732099 - Rev.D
J6
60 W ma
x
17 16 1415 13
M
L
N
MOT COM
MOT1
MOT2
LAMP
J5 J9
J4
J3
Translation of the original instructions
ENGLISH
7 Board technical data
780D [230 V~] 780D [115 V~]
Power supply voltage 220-240 V~ 50/60 Hz 115 V~ 50/60 Hz
Max power 10 W 10 W
Max. motor power 1000 W 1200 W
Max accessories load 24 V
"
500 mA 500 mA
Ambient operating temperature -20°C to +55°C -20°C to +55°C
Flashing light 230 V~ - 60 W 115 V~ - 60 W
7.3 CONNECTIONS
F
Carry out the work with the power supply disconnected.
!
Do not exceed the maximum load of the outputs.
MOTOR
The connection to terminal board J6 is carried out at the factory (34).
!
DO NOT modify the factory connection. If the direction of rotation of the
motor has to be reversed, modify function dl in basic programming.
TERMINAL BOARD J6
15 COM Common (grey or blue)
16
17
MOT 1
MOT 2
Phase (black)
Phase (brown)
FLASHING LIGHT
Connect the flashing light to terminal board J6 (34).
MAGNETIC ENCODER
The magnetic encoder sensor detects the rotation of the magnet on
the shaft (34).
The sensor is integrated in the board and does not need to be con-
nected.
STARTUP CAPACITOR
Connected at the factory: rapid connector J5 (35).
TRANSFORMER
The transformer is factory installed (connectors J3-J4) (35).
MAGNETIC LIMIT STOP SENSOR
Connected at the factory: rapid connector J9 (35).
transformer
magnet

Table of Contents