EasyManua.ls Logo

FAAC 746 E R Z20 - Programming the Board; Restoring Factory Settings; Basic Programming; Advanced Programming

FAAC 746 E R Z20
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
746 E R 29 732099 - Rev.D
F
-
+
Translation of the original instructions
ENGLISH
8.2 PROGRAMMING THE BOARD
F
Programming must be carried out with the board cover installed.
8 Basic programming
BASIC FUNCTION Default
LO
Operating logic:
EP
A Automatic
AP Automatic step by step
S Automatic Safety
E Semi-automatic
EP Semi-automatic step by step
C Dead-man
b Semi-automatic B
bC Mixed (b opening / C closing)
PA
Pause time (carried out in the automatic logics).
004.1 adjustment in steps of 1 s from 0 to 59, then in steps of
10 s
E.g.
41 = 41 s ; 4.1 = 4 min and 10 s (max time)
2.0
FO
Electronic force of gearmotor
0150 (max)
50
dI
Opening direction of the leaf, established by looking at the 746 E R from
the release device side.
-3 Opens towards the right
E- Opens towards the left
-3
St
Exit from programming mode and display the status of the automation:
00 Closed
01 Opening
02 Stopped
03 Open
04 Open in pause
05 Failsafe test failed
06 Closing
07 Reversing
08 Photocells tripped
9 Advanced Programming
ADVANCED FUNCTION Default
bo
Maximum torque at initial thrust
Y enabled
no not enabled
Y
Sr
Slow movement every time power is turned on / restored
Y enabled
no not enabled
no
br
Final braking
00 not enabled
0120 adjustment in steps of 0.1 s E.g. 20 = 2 s (max time)
05
FS
FailSafe test on inputs FSW CL and FSW OP
Y enabled
no not enabled
no
SA
FailSafe test on SAFE input
Y enabled
no not enabled
no
PF
Pre-flashing of 5 s on the LAMP output
no not enabled
oP enabled before opening
CL enabled before closing
OC enabled before opening and closing
no
SP
Output W.L. configuration
00 LED
01
4.1 courtesy light activation time. Adjustment in steps of 1
s from 0 to 59, then in steps of 10 s. E.g. 41 = 41 s ; 4.1 = 4 min
and 10 s (max time)
When
00 is displayed, press the
-
button to select:
E1 closing electric lock
E2 opening and closing electric lock
E3 traffic light control on when the automation is open
E4 traffic light control on when the automation is closed
00
Access the basic programming menu
- When the display indicates the status of the automation, press
and hold down the
F
button: the display shows the first func-
tion: LO. The function is displayed as long as button F remains
pressed.
- Release button
F
: the display shows the value of the function.
Access the advanced programming menu
- When the display indicates the status of the automation, press
and hold down the
F
button, then press the
+
button as well: the
display shows the first function: bO. The function is displayed
as long as the
F
button remains pressed.
- Release the buttons: the display shows the value of the function.
Modifying the basic / advanced programming settings
- When the display indicates the value of the function, press the
+
or
-
button to modify it.
Modifications to the values are made and saved immediately.
- Press button
F
to go to the next function. The function is dis-
played as long as the
F
button remains pressed.
- To exit from the programming mode, scroll through the menu
until you reach the
St function and release the button. The
display reverts to the automation status view.
RESTORING FACTORY SETTINGS
This procedure restores all the default values.
1. Make sure that the SAFE input is closed (LED on) and that the display
indicates the status of the automation.
2. Press and hold down the
+
and
-
buttons simultaneously, then also
the
F
button for at least 5 s. When t and S alternate on the dis-
play, release the buttons: the default values have been restored.

Table of Contents

Related product manuals