E145 18 732784 - Rev. A
F
F
-/
R2
+/
R1
F
F
+
+/
R1
F
+
+/
R1
ENGLISH
5. PROGRAMMING
Programming is divided in two levels:
• BASIC programming
• ADVANCED programming
The programming phases are (see Tab.):
1. to access PROGRAMMING (1A or 1B);
2. to show the set values and modify them, if you
want. Changing the values is effective imme-
diately, while the final memorisation must be
carried out upon exiting programming (
St).
3. exit the programming by using
St function. Select
Y to SAVE the configuration you just perfor-
med, otherwise select
no to EXIT WITHOUT
SAVING any changes.
You can EXIT programming at anytime:
press and hold F and then also
-
to switch
directly to
St.
F
+
-
/
R2
This board also allows programming using a PC
or MAC.
This programming requires connection to PC/
MAC via USB cable and USB-B relevant port, or
by using the X-COM module.
The programming SOFTWARE with relevant in-
structions, must be downloaded from the website:
www.faacgroup.com
www.faacgroup.com
The programming using a PC/MAC, with the de-
fault PASSWORD does not inhibit the program-
ming by board. The writing
PC will be displayed in
correspondence with the modified values. Notes:
when you modify the values by board the previous
PC/MAC programming will be overwrote.
The default password is 0000.
The programming using a PC/MAC, with a modi-
fied PASSWORD (different from the default one),
will inhibit the programming by board. If one of the
buttons is pressed, the display will show
PC pro-
gramming for 5 sec and changes will be allowed
only by PC /MAC.
❶❷
BASIC PROGRAMMING
1A. PRESS AND HOLD F :
THE FIRST FUNCTION APPEARS
1
RELEASE F:
THE FUNCTION VALUE
IS DISPLAYED
USING
+
OR
-
,
SCROLL THE
AVAILABLE VALUES
UNTIL THE THE
DESIRED ONE
PRESS
F:
TO MOVE TO
THE NEXT
FUNCTION
1
FUNCTION St
(LAST BASIC OR ADVANCED
FUNCTION)
ADVANCED PROGRAMMING
1B. PRESS AND HOLD F AND
THEN ALSO
+
:
THE FIRST FUNCTION APPEARS
1
RELEASE THE KEYS:
THE FUNCTION VALUE
IS DISPLAYED
SELECT
Y TO SAVE THE
PROGRAMMING
OTHERWISE
SELECT
no TO EXIT THE
PROGRAMMING WITHOUT
SAVING
1
THE FUNCTION IS DISPLAYED UNTIL YOU HOLD
Tab. Programming phases.

Other manuals for FAAC E145