9. TROUBLESHOOTING
Description Solution
A
The board does not turn on
Ensure that the board is receiving the 230V~
Ensure that fuse F1 is intact
B
The gate will not open after
an OPEN pulse
Check that the safety devices and STOP are connected
to the negative and ensure that the corresponding LEDs
are ON
Check the photocells (alignment, engagement)
Check that the SETUP has been completed correctly.
Repeat if necessary
C
The gate does not reverse
when the photocells are
engaged
Check that the traditional photocells are correctly wired and
that the BUS photocell configuration is correct (if present).
If necessary, repeat the acquisition of the BUS-2EASY
devices
D
The gate does not reverse
when encountering
an
obstacle
Ensure that the encoders on motors are enabled
Check the obstacle detection sensitivity
E
The gate will not close
Check that the photocell wiring and alignment is correct
Check that there is no OPEN signal active
Check which function logic has been chosen (automatic
or semi-automatic)