E145 8 732784 - Rev. A
MAX
100 mA
{
C1 C2
J12J3J2
J1
9 10 11 12 13 14 15 16 17 18 19
20 21 22
PE N L
1 2 3 4 5 6 7 8
AC MAIN
PE N L
M1
123
LOCK
21
OUT
2
20
OUT
1
19
IN
2
IN
1
IN
3
IN
4
IN
5
22
LAMP
78
24V
3W
230V~
MAX 60W
Mot1 Mot2
COM OP CL
OP-A 1
LOCK
2OP-B STOP CL
FSW
OP
-
14
-
15
-
16
+
17
+
1891011 1213
24V
M2
456
COM OP CL
MIN 90V~
MAX 260V~
50/60 Hz
12V ~
24V
12V ~
24V
* *
J1 J2 J3
J12
{
MAX
500 mA
{
ENGLISH
4. ELECTRICAL CONNECTIONS
4.1 J1 - MAINS PRIMARY POWER SUPPLY
PE Earthing Connection
For correct operation, you must con-
nect the switching power supply to the
system’s earthing conductor. Ensure
that upstream a suitable differential
magnetothermic switch has been in-
stalled.
N
Power Supply Connection from 90 V~ to 260
V~ Neutral
L
Power Supply Connection from 90 V~ to 260
V~ Line
Motor for SINGLE-LEAF or
FIRST
LEAF when opening
(closes for the second)
OPEN A
Total gate opening
(contact N.O.)
OPEN B
Partial gate ope-
ning (contact N.O.)
STOP
Gate stop
(contact
N.C.)
*
Blue or grey
Photocells and safety de-
vices: for connections, see
the related paragraph.
4.2 J2 - MOTORS AND FLASHING LAMP
1 M1 - COM Common contact motor 1
M1 = first leaf when opening or single leaf
M2 = second leaf when opening - CAN-
NOT be used for single leaf
To verify correct wiring and direction
of motor rotation, (see 5.4 TIME LEAR-
NING - SETUP)
2 M1 - OP Opening phase motor 1
3 M1 - CL Closing phase motor 1
4 M2 - COM
Common contact motor 2
5 M2 - OP Opening phase motor 2
6 M2 - CL Closing phase motor 2
7
LAMP Flashing lamp connection (MAX 60 W)
8