EasyManua.ls Logo

FAAC E145 - J3 - Low-Voltage Accessories - Inputs;Outputs

FAAC E145
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E145 9 732784 - Rev. A
ENGLISH
4.3 J3 - LOW-VOLTAGE ACCESSORIES - INPUTS/OUTPUTS
9 IN1
OPEN A contact - N.O.
TOTAL opening
Connect a button or other pulse generator which, by closing
a contact, commands TOTAL opening of both leaves.
10 IN2
OPEN B contact - N.O.
PARTIAL opening
Connect a button or other pulse generator which, by closing
a contact, commands the PARTIAL opening.
on 2-motor systems = 100% of leaf 1 opening;
on 1-motor systems = 50% of leaf 1 opening.
When a logic requiring a CLOSE (
b
,
bC
,
C
) input is selected,
the, OPEN B input automatically becomes CLOSE - N.O. (lea-
ves closing command).
To install more than one OPEN A or OPEN B pulse generator, connect the N.O. contacts in
parallel (see related Fig.)
11 IN3
STOP contact - N.C.
Connect a button or other pulse generator which, by opening
a contact, stops movement of the automated system.
To install more than one STOP device, connect the N.C. contacts in series (see related Fig.).
If stop devices are NOT connected, jumper the terminals STOP and GND.
12 IN4
FSW CL contact - N.C.
closing safety
Connect a photocell or other device which, by opening a con-
tact, reverses the movement of the automated system during
opening (FSW OP) or during closing (FSW CL).
13 IN5
FSW OP contact - N.C.
opening safety
To install more than one safety device, connect the N.C. contacts in series (see related Fig.).
If safety devices are NOT connected, jumper terminals IN4 and IN5 and GND if the FAIL-SAFE
safety is not active; otherwise jumper IN4 and IN5 and OUT1 (FAIL-SAFE).
14
- GND Accessories power supply negative15
16
17
+ +24 Accessories power supply positive (MAX. load = 500mA)
18
19 OUT1
24 V
"
(Open Collector) programmable using function
o1
(advanced programming);
default: always active.
Other programming options are available by programming via a PC/MAC (see dedicated
instructions).
Fig. e.g.: Connecting 2 N.O. contacts in parallel. Fig. e.g.: Connecting 2 N.C. contacts in series.