5.1 BASIC PROGRAMMING FUNCTIONS
Display Basic Function
Default
CF
MOTOR TYPE:
Displays and allows you to change the motor type set on the board:
1 Motors for swing-leaf gates
2 Motors for sliding gates
PC Mixed configuration from a PC/MAC (e.g.: a swing and a slide)
At the time of changing the set motor type on the board, the
relevant defaults are uploaded.
dF
DEFAULT:
Y indicates that all the set values correspond to the default values.
no indicates that one or more set values are different from the default.
Set
Y if you want to restore the default settings.
Y
LO
FUNCTION LOGICS:
E Semi-automatic
EP Semi-automatic Step-by-Step
S Automatic Safety Devices
SA Automatic with reversal during pause
SP Automatic Step-by-Step Safety Devices
A1 Automatic 1
A Automatic
AP Automatic Step-by-Step
At Automatic timer
b Semi-automatic “b”
bC Mixed (Pulses for opening / Dead-man commands for closing)
C Dead-man
CU Logic modified from a PC/MAC
When a logic requiring a CLOSE (b, bC, C), input is selected,
the OPEN B inputs will automatically be changed to CLOSE. , if
you choose a logic that does not require the use of CLOSE inputs,
these inputs will change to OPEN B. The simultaneous presence
of CLOSE and OPEN B is possible only using the PC/MAC software.
For a description of how the logics operate, see the related paragraph.
E