8.2 ALARMS
When there is an ALARM the ERROR LED will begin to flash. By simultaneously pressing +
and - the display will show the corresponding alarm number.
The following table contains all the alarms that can be viewed on the display.
N° ALARM Solution/Description
20
Obstacle on MOTOR 1 (only with
encoder)
Remove any possible obstacle on leaf 1
21
Obstacle on MOTOR 2 (only with
encoder)
Remove any possible obstacle on leaf 2
25
LOCK 1 output short-circuit Remove the cause of the short-circuit
26
LOCK 2 output short-circuit Remove the cause of the short-circuit
27
Nr. of consecutive obstacles
exceeded during opening
Remove any possible obstacle.
Should the problem persist, repeat SETUP
28
Nr. of consecutive obstacles
exceeded during closing
Remove any possible obstacle.
Should the problem persist, repeat SETUP
30
XF radio code memory full
Cancel the radio codes that are not being used using
the PC program or use an additional DEC/MINIDEC/
RP module
35
TIMER active and TIMER function
operating:
TIMER function is operating
40
Service request Contact the installer for maintenance
50
The HOLD POSITION is operating
(active on PC/MAC )
HOLD POSITION function is operating
60
TIMER active and error in TIMER
data
Reload a correct TIMER configuration with the PC/MAC
programme
62
Loss of time and date on the board
(only if the TIMER is operating)
Reload the time and date with the PC/MAC programme
and replace the BAT1 - CR2032 buffer battery
63
JOLLY TIMER is activated JOLLY TIMER is enabled by terminal board J3
64
TIMER DISABLED is operating TIMER is disabled by terminal board J3