E145 29 732784 - Rev. A
ENGLISH
Display Advanced Function
Default
nd
CYCLE PROGRAMMING (TENS):
If
AS = Y the display will show the number of tens of cycles after which the
signaling of maintenace request begins (can be set from
0 to 99).
If
AS = no the display will show the number of tens of work cycles performed.
The value displayed is updated with the succession of the cycles,
interacting with the value in
nc.
e.g.: if the system has performed 11,218 cycles, nc = 11 and nd = 21
will be displayed
00
St
AUTOMATED SYSTEM STATUS:
You can exit programming, choosing whether or not to save the configuration
you just performed.
1. set the choice:
Y to SAVE and EXIT the programming
no to EXIT the programming WITHOUT SAVING
2. press the button F to confirm; at the end the display returns to visualize
the automated system status:
Y
00 = CLOSED
01 = OPEN
02 = Stationary then “OPENS”
03 = Stationary then “CLOSES”
04 = In “PAUSE”
05 = Opening
06 = Closing
07 = FAIL SAFE in progress
08 = checking BUS-2EASY devices in progress
09 = Pre-flash then “OPENS”
10 = Pre-flash then “CLOSES”
11 = Emergency open
12 = Emergency close
HP = Hold position
WARNING If power is lost to the board prior to confirmation (step
2.), all changes made will be lost.
F
+
-
/
R2
You can EXIT programming at any time: press and hold F and
then also
-
to switch directly to St.