E145 50 732784 - Rev. A
ENGLISH
1
if the cycle began with OPEN-B, opens totally
2
operation can be modified by programming
3
it opens if, at power up, an OPEN (A or B) command is active. Otherwise it closes.
AP
AP
AUTOMATICSTEP-BY-STEPLOGIC
PULSES
AUTOMATED
SYSTEM
STATUS
OPEN
A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED
OPENS
;
CLOSES AFTER
PAUSE TIME
OPENS
PARTIALLY;
CLOSES AFTER
PAUSE TIME
NO
EFFECT NO EFFECT (OPEN DISABLED) NO EFFECT
NO
EFFECT (OPEN
DISABLED)
OPENING
STOPS
*
1
STOPS* CLOSES STOPS*
REVERSES
(
SAVES OPEN)
NO EFFECT
STOPS
; OPENS AT
RELEASE
(
OPEN STOPS* -
SAVES CLOSE)
OPEN IN PAUSE
STOPS
*
1
STOPS* CLOSES STOPS* NO EFFECT
RECHARGES
PAUSE TIME (CLOSE DISABLED)
CLOSING OPENS NO EFFECT STOPS* NO EFFECT
REVERSES
2
STOPS;
OPENS AT
RELEASE
(OPEN STOPS*
-
SAVES CLOSE)
*
STOPPED CLOSES
NO
EFFECT
(
OPEN/CLOSE
DISABLED)
NO EFFECT
(
OPEN
DISABLED)
NO EFFECT
(
CLOSE
DISABLED)
NO EFFECT (OPEN/
CLOSE DISABLED)
PULSES
AUTOMATED
SYSTEM
STATUS
OPEN
A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED
OPENS
;
CLOSES AFTER
PAUSE TIME
OPENS
PARTIALLY;
CLOSES AFTER
PAUSE TIME
NO
EFFECT NO EFFECT (OPEN DISABLED) NO EFFECT
NO
EFFECT
(
OPEN DISABLED)
OPENING
NO
EFFECT
1
NO EFFECT CLOSES STOPS* REVERSES NO EFFECT
STOPS
; OPENS AT
RELEASE
(
SAVES CLOSE)
OPEN IN PAUSE
RECHARGES
PAUSE
TIME
1
RECHARGES
PAUSE TIME
CLOSES STOPS
* NO EFFECT
RECHARGES
PAUSE TIME (CLOSE DISABLED)
CLOSING OPENS NO EFFECT STOPS* NO EFFECT
REVERSES
2
STOPS; OPENS
AT RELEASE
(
SAVES CLOSE)
*
STOPPED CLOSES
NO
EFFECT
(
OPEN/CLOSE
DISABLED)
NO EFFECT
(
OPEN
DISABLED)
NO EFFECT
(
CLOSE
DISABLED)
NO EFFECT (OPEN/
CLOSE DISABLED)
A