Remote modules
CNC 8060
CNC 8065
5.
(REF: 1402)
·101·
RIOW REMOTE MODULES. (CANOPEN PROTOCOL).
5.12 RIOW-2AI-PT100 module. Module of 2 inputs for PT100
temperature sensors.
Expansion module with 2 analog inputs for PT100 temperature sensors. Each input has an
LED indicating the status of the bus an LED indicating a measuring error of the sensor.
48
15
26
37
C
A
D
B
RL signal of the sensor ·1·
R- signal of the sensor ·1·
Shield connection.
R+ signal of the sensor ·1·
RL signal of the sensor ·2·
R- signal of the sensor ·2·
Shield connection.
R+ signal of the sensor ·2·
Bus status indicator LED for
sensor ·1·.
LED indicating an error at sensor
·1·; reading error or broken cable.
Bus status indicator LED for
sensor ·2·.
LED indicating an error at sensor
·2·; reading error or broken cable.