Remote modules
CNC 8060
CNC 8065
3.
(REF: 1402)
·31·
RIO70 REMOTE MODULES. (CANFAGOR PROTOCOL).
3.3.1 Elements (connectors).
Connector ·X1·. Power and emergency relay.
6-pin male Phoenix minicombicon contact (3.5 mm pitch).
The relay may be used to connect the modules to the emergency chain of the electrical
cabinet. The relay is an internal contact that closes when the group is ready; it opens again
when an internal failure occurs.
·OVER VOLTAGE· button and status LED.
This button may be used to reactivate the power supply after an over-current. An over-current
activates the safety device inside the power supply turns on the external red LED. The power
supply will not be operative while the LED is on. There are two ways to reactivate the power
supply after an over-current.
Unplug the power supply from mains and wait for about 30 seconds until the red light turns
off.
Unplug the power supply and press the button. The red LED will turn off indicating that
the power supply is ready.
If after reactivating the power supply, the LED turns back on, call the Technical Service
Department.
·SYSTEM READY· LED. Module under power.
·OVER CURRENT· LED. Over-current at the power supply.
·ERROR· LED. Error at the power supply.
·POWER· LED. Status of the 5 V.
·RESET· button.
The ·RESET· button may be used to reset the module after changing the node address;
however, it is recommended to change the address while the modules and the CNC are off.
The LED is green. This LED blinks when the module is under
power.
Red LED. This LED turns on when the +5 V power supply is
outputting the maximum current.
Red LED. This LED turns on when the power supply is not capable
of supplying the 5 V DC due to a current overload
To eliminate the error, remove the load from the power supply or
duplicate the group.
The LED is green. This LED turns on when the +5 V power supply
is working properly.
Signal. Function.
Chassis Shield.
GND IN Power input.
GND IN Power input.
+ 24 V Power input.
System
Ready
Relay for the emergency chain.
POWER
+ 5 ERROR
+5 OVER CURRENT
SYSTEM READY
POWER
+ 5 ERROR
+5 OVER CURRENT
SYSTEM READY
POWER
+ 5 ERROR
+5 OVER CURRENT
SYSTEM READY
POWER
+ 5 ERROR
+5 OVER CURRENT
SYSTEM READY