7.6.1 Error codes. Meaning and solution.
E034 Error identifying the CPU board.
Contact Fagor Automation.
E038 Code checksum error.
The loaded checksum of the program code is not correct. Load the software again. If the problem
persists, the RAM, FLASH memories or the loaded code may be defective. Contact Fagor Automation.
E039 Error on the Sercos ® board .
Contact Fagor Automation.
E040 Failure of the clock of the SerCon® board.
Contact Fagor Automation.
E041 SerCon memory corrupted.
Contact Fagor Automation.
E044 Corrupted file system in flash.
Contact Fagor Automation.
E045 Error reading analog offsets.
Contact Fagor Automation.
E046 Error identifying the axis board.
Contact Fagor Automation.
E047 Unknown axis board identification.
Contact Fagor Automation.
E04 Error in FPGA code.
The FPGA code seems to be corrupted or is missing. Try reloading the software version. If the problem
persists, the RAM, FLASH memories or the loaded code may be defective. Contact Fagor Automation.
E083 The FPGA could not be loaded.
Restart the counter. If the problem persists, contact Fagor Automation.
0084 Reset due to Watchdog.
The system has restarted because watchdog kicked in. If the problem is repetitive and/or persists,
contact Fagor Automation.
E085 Error in power supply for the analog outputs.
Contact Fagor Automation.
E133 Broken wire, A signal of E21A feedback.
E233 Broken wire, A signal of E21B feedback.
E333 Broken wire, A signal of E21C feedback.
E433 Broken wire, A signal of E21D feedback.
For differential TTL feedback. The A and/or /A signal wire may be broken or disconnected.
Check the connection. Check the level of the signals provided by the feedback device.
E134 Broken wire, B signal of E21A feedback.
E234 Broken wire, B signal of E21B feedback.
E334 Broken wire, B signal of E21C feedback.
E434 Broken wire, B signal of E21D feedback.
For differential TTL feedback. The B and/or /B signal wire may be broken or disconnected.
Check the connection. Check the level of the signals provided by the feedback device.
E135 Broken wire, I0 signal of E21A feedback.
E235 Broken wire, I0 signal of E21B feedback.
E335 Broken wire, I0 signal of E21C feedback.
E435 Broken wire, I0 signal of E21D feedback.
For differential TTL feedback. The I0 and/or /I0 signal wire may be broken or disconnected. Check the
connection. Check the level of the signals provided by the feedback device.