·132·
Remote modules
CNC 8060
CNC 8065
7.
(REF: 1402)
REMOTE MODULE RCS-S. (SERCOS PROTOCOL)
7.7 Software installation/update.
Requirements.
The software of the remote module "RCS-S" (Sercos counter) can only be installed/updated
using Fagor's PC application "WinDDSSetup" with version 08.06 or later.
Therefore, to do that, WinDDSSetup must be previously installed at the PC and the remote
module RCS-S must be connected to the PC through an RS-232 serial line cable.
Process.
If the "Online" option is shown, uncheck it to enable the "Boot" option. Its associated icon
will also be enabled on the tool bar.
BOOT.
Proceed as follows:
Run the WinDDSSetup application at the PC.
Select the label "Work mode" and check the "Boot"option of the pop-up menu.
Click on the "Boot" icon of the tool bar to display the "BootType" window.
Select "BOOT_RCS_S" from the list and click on "validate". That will display the "BootStrap"
window.