EasyManua.ls Logo

Fagor CNC 8060 - Page 131

Fagor CNC 8060
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote modules
CNC 8060
CNC 8065
7.
(REF: 1402)
·131·
REMOTE MODULE RCS-S. (SERCOS PROTOCOL)
E198 Fagor digital feedback. Parameter error.
E298 Fagor digital feedback. Parameter error.
E398 Fagor digital feedback. Parameter error.
E498 Fagor digital feedback. Parameter error.
Rotary or linear encoder configuration has been lost. Replace the rotary encoder or the reader head
of the linear encoder.
E403 MST failure.
Communication problems through fiber optic ring. Check the ring connections and the identification of
each module.
E404 MDT failure.
Communication problems through fiber optic ring. Check the ring connections and the identification of
each module.
E405 Invalid phase(>4).
Communication problems through fiber optic ring. Check the ring connections and the identification of
each module.
E406 Phase up-shift error.
Communication problems through fiber optic ring. Check the ring connections and the identification of
each module.
E407 Phase down-shift error.
Communication problems through fiber optic ring. Check the ring connections and the identification of
each module.
E410 Noise resets Sercon.
Noise gets in through the connection of the internal bus resetting the SerCon but not with the VeCon2.
E411 Error when receiving telegrams.
Communication problems through fiber optic ring. Check the ring connections and the identification of
each module.
E412 Delayed synchronism message.
Communication problems through fiber optic ring. Check the ring connections and the identification of
each module.
E413 Handshake error in Sercos counter.
The master element (CNC) sends a synchronism message in every cycle (usually 4ms) that
synchronizes the drives. This error appears when they can't synchronize or lose synchronism.
Maybe the CNC has not sent this message or if it has, it wasn't in the precise moment. Check the
transmission cable or check that there is no noise in the transmission.