EasyManua.ls Logo

Fagor CNC 8060 - Page 121

Fagor CNC 8060
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote modules
CNC 8060
CNC 8065
7.
(REF: 1402)
·121·
REMOTE MODULE RCS-S. (SERCOS PROTOCOL)
Connector ·I37A·. 2 general purpose ±10 V analog outputs (16-bit resolution).
2x2 pin two-level male Phoenix minicombicon contact (3.5 mm pitch).
Connector ·I37B·. 2 general purpose ±10 V analog outputs (16-bit resolution).
2x2 pin two-level male Phoenix minicombicon contact (3.5 mm pitch).
Connector ·H53·. RS232 serial line.
Simple RS232 communication (only RX and TX) for updating the module.
Signal. Function.
AO1
AO2
Analog output.
GND
GND
0 V reference signal.
AO1
GND
AO2
GND
Signal. Function.
AO3
AO4
Analog output.
GND
GND
0 V reference signal.
AO3
GND
AO4
GND

Table of Contents

Other manuals for Fagor CNC 8060

Related product manuals