REMOTE MODULE RCS-S. (SERCOS PROTOCOL)
E145 ABSIND: Synchronism error at E21A feedback.
E245 ABSIND: Synchronism error at E21B feedback.
E345 ABSIND: Synchronism error at E21C feedback.
E445 ABSIND: Synchronism error at E21D feedback.
Synchronism lost between the Sercos counter and the ABSIND module which may have caused a wrong
position reading. The error may be due to wrong performance of the ABSIND moduel or to a connection
problem between the ABSIND module and the Sercos counter associated with that feedback.
If the problem persists, contact Fagor Automation.
E146 ABSIND: Error reading information at E21A feedback.
E246 ABSIND: Error reading information at E21B feedback.
E346 ABSIND: Error reading information at E21C feedback.
E446 ABSIND: Error reading information at E21D feedback.
It could not read the ABSIND module identification info during system startup. The error may be due
to wrong performance of the ABSIND moduel or to a connection problem between the ABSIND module
and the Sercos counter associated with that feedback.
If the problem persists, contact Fagor Automation.
E183 INDUCTOSYN: INC signal too low at E21A feedback.
E283 INDUCTOSYN: INC signal too low at E21B feedback.
E383 INDUCTOSYN: INC signal too low at E21C feedback.
E483 INDUCTOSYN: INC signal too low at E21D feedback.
Incremental signal level of the inductosyn/resolver feedback device too low. Check the gain and phase
values of the ABSIND module with the adjustment software. Check the cable and the connection
between the ABSIND module and the inductosyn/resolver feedback device. If the error persists and
cannot be changed with the previous actions, try replacing the ABSIND module and/or the cable
associated with that feedback. If the error persists, contact Fagor Automation.
E184 INDUCTOSYN: INC signal too high at E21A feedback.
E284 INDUCTOSYN: INC signal too high at E21B feedback.
E384 INDUCTOSYN: INC signal too high at E21C feedback.
E484 INDUCTOSYN: INC signal too high at E21D feedback.
Incremental signal level of the inductosyn/resolver feedback device too high. Check the gain and phase
values of the ABSIND module with the adjustment software. Check the cable and the connection
between the ABSIND module and the inductosyn/resolver feedback device. If the error persists and
cannot be changed with the previous actions, try replacing the ABSIND module and/or the cable
associated with that feedback. If the error persists, contact Fagor Automation.
E185 INDUCTOSYN: GRAY signal missing at E21A feedback.
E285 INDUCTOSYN: GRAY signal missing at E21B feedback.
E385 INDUCTOSYN: GRAY signal missing at E21C feedback.
E485 INDUCTOSYN: GRAY signal missing at E21D feedback.
GRAY signal level of the inductosyn/resolver feedback device missing. Check the gain and phase values
of the ABSIND module with the adjustment software. Check the cable and the connection between the
ABSIND module and the inductosyn/resolver feedback device. If the error persists and cannot be
changed with the previous actions, try replacing the ABSIND module and/or the cable associated with
that feedback. If the error persists, contact Fagor Automation.
E186 INDUCTOSYN: Linear encoder unstable on Power-ON, E21A feedback.
E286 INDUCTOSYN: Linear encoder unstable on Power-ON, E21B feedback.
E386 INDUCTOSYN: Linear encoder unstable on Power-ON, E21C feedback.
E486 INDUCTOSYN: Linear encoder unstable on Power-ON, E21D feedback.
The position read when initializing the ABSIND module is unstable. Check that the axis is not moving
while starting up or initializing. Check the cable and the connection between the ABSIND module and
the inductosyn/resolver feedback device. Check the ground connections in the electrical cabinet
(electrical noise on the signals). If the error persists and cannot be changed with the previous actions,
try replacing the ABSIND module and/or the cable associated with that feedback. If the error persists,
contact Fagor Automation.
E187 INDUCTOSYN: Wrong EEPROM checksum, E21A feedback.
E287 INDUCTOSYN: Wrong EEPROM checksum, E21B feedback.
E387 INDUCTOSYN: Wrong EEPROM checksum, E21C feedback.
E487 INDUCTOSYN: Wrong EEPROM checksum, E21D feedback.
Check the gain and phase values of the ABSIND module with the adjustment software. If the error
persists and cannot be changed with the previous actions, try replacing the ABSIND module associated
with that feedback. If the error persists, contact Fagor Automation.