·134·
Remote modules
CNC 8060
CNC 8065
7.
(REF: 1402)
REMOTE MODULE RCS-S. (SERCOS PROTOCOL)
After clicking on OK, the next time the "Boot" icon of the tool bar is pressed on the home
screen of WinDDSSetup, it will no longer display the "BootType" window. It will select directly,
by default, the option that is selected now on the pop-up menu "Default Boot Type", which
in this case is "BOOT_RCS_S" as shown in the screenshot.
Communication parameters
SetUp> Preferences> Communication
Use this menu to set the main parameters involved in the communication between the PC
and the remote module "RCS-S". They stay by default when starting a new session with
WinDDSSetup. Any changes made in this dialog box has an immediate effect.
Port. Select the communication port.
Options: COM1 or COM2.
Speed (bd). Select communication speed.
Options: 9600 or 19200.
Protocol. Select communication protocol.
Options: DNC50 - Monoslave, DNC50 - Multislave, MODBUS-RTU or
MODBUS-ASCII.
Connection. Select connection through RS-232 or RS-422 serial line after selecting
MODBUS RTU or ASCII protocol.