EasyManua.ls Logo

Fagor CNC 8060 - Page 14

Fagor CNC 8060
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
·14·
Remote modules
CNC 8060
CNC 8065
(REF: 1402)
PRECAUTIONS AGAINST PRODUCT DAMAGE
PROTECTIONS OF THE UNIT ITSELF
Working environment. This unit is ready to be used in industrial environments complying with
the directives and regulations effective in the European Community.
Fagor Automation shall not be held responsible for any damage
suffered or caused by the CNC when installed in other environments
(residential or homes).
Install the unit in the right place. It is recommended, whenever possible, to install the CNC away from
coolants, chemical product, blows, etc. that could damage it.
This unit complies with the European directives on electromagnetic
compatibility. Nevertheless, it is recommended to keep it away from
sources of electromagnetic disturbance such as:
Powerful loads connected to the same AC power line as this
equipment.
Nearby portable transmitters (Radio-telephones, Ham radio
transmitters).
Nearby radio/TV transmitters.
Nearby arc welding machines.
Nearby High Voltage power lines.
Enclosures. The manufacturer is responsible of assuring that the enclosure
involving the equipment meets all the currently effective directives of
the European Community.
Avoid disturbances coming from the
machine.
The machine must have all the interference generating elements
(relay coils, contactors, motors, etc.) uncoupled.
Use the proper power supply. Use an external regulated 24 Vdc power supply for the keyboard and
the remote modules.
Grounding of the power supply. The zero volt point of the external power supply must be connected
to the main ground point of the machine.
Analog inputs and outputs connection. Use shielded cables connecting all their meshes to the corresponding
pin.
Ambient conditions. The storage temperature must be between +5 ºC and +55 ºC (41 ºF
and 131 ºF).
The storage temperature must be between -25 ºC and 70 ºC (-13 ºF
and 158 ºF).
Central unit enclosure. Make sure that the needed gap is kept between the central unit and
each wall of the enclosure.
Use a DC fan to improve enclosure ventilation.
Main AC power switch. This switch must be easy to access and at a distance between 0.7 and
1.7 m (2.3 and 5.6 ft) off the floor.
Remote modules. All the digital inputs and outputs have galvanic isolation via
optocouplers between the CNC circuitry and the outside.