Loading...
Remote modules
CNC 8060
CNC 8065
8.
(REF: 1402)
·141·
CAN BUS (CANFAGOR/CANOPEN PROTOCOLS).
To save the selected speed, put dipswitch ·8· in the ·on· position. After saving the
configuration, the corresponding LED's turn on to indicate the module speed. For 1 MHz,
all four LED's turn on.
Once the speed has been selected, turn the module off by removing power and set dip-switch
·8· in the ·off· position. Bear in mind that the next time the module is turned on, the position
of the dipswitches will indicate the address (node number) of the group.
ON Off Off Off 800 kHz
Off ON Off Off 500 kHz
ON ON Off Off 250 kHz
Dipswitch ·1· Dipswitch ·2· Dipswitch ·3· Dipswitch ·4· Speed