·54·
Remote modules
CNC 8060
CNC 8065
4.
(REF: 1402)
RIO5 REMOTE MODULES. (CANOPEN PROTOCOL).
Connectors for the analog inputs and outputs.
Connector ·X4·. General purpose analog outputs (4 outputs).
12-pin male Phoenix minicombicon contact (3.5 mm pitch).
Each analog output has three pins (O+, O-, SH). Use shielded cables connecting their
meshes to the corresponding shield pin.
Connector ·X6·. Differential analog inputs (4 inputs).
15-pin male Phoenix minicombicon contact (3.5 mm pitch).
Each analog input has three pins (I+, I-, SH). Use shielded cables connecting their meshes
to the corresponding shield pin.
Connectors for the temperature sensors PT100.
Connector ·X5·. Inputs for temperature sensors PT100 (2 inputs).
10-pin male Phoenix minicombicon contact (3.5 mm pitch).
Signal. Function.
O1+ O1- Analog outputs.
O2+ O2- Analog outputs.
O3+ O3- Analog outputs.
O4+ O4- Analog outputs.
SH Shield connection.
SH
O1+
X4
O1-
SH
O2+
O2-
SH
O3+
O3-
SH
O4+
O4-
+12
I1+
I1-
SH
GN D
X6
I2+
I2-
SH
I3+
I3-
I4+
I4-
-12
SH
SH
Signal. Function.
I1+ I1- Analog inputs.
I2+ I2- Analog inputs.
I3+ I3- Analog inputs.
I4+ I4- Analog inputs.
SH Shield connection.
+12 -12 12 V output.
GND 0 V reference signal.
Signal. Function.
R1+ R1-
RL1 RF1
Signals of the PT100 sensor.
R2+ R2-
RL2 RF2
Signals of the PT100 sensor.
SH Shield connection.
X5
R1+
RL1
SH
RF2
R1-
RF1
SH
RL2
R2+
R2-

Table of Contents