Maintenance - 1000h
4812158701_G.pdf2019-10-01
Fig. Left drum side
1. Filler plug
2. Drain plug
3. Sight glass
1
2
3
The oil should now come up to the sight glass (3).
If necessary, release the filler plug (1) and fill to half
the sight glass (3).
Clean the magnetic filler plug (1) of any metallic
residue, before refitting the plug.
Ensure that only Dynapac Drum Oil 1000 is used
in the cartridges.
Ensure that only Dynapac Drum Oil 1000 is used
in the cartridges.
Do not overfill with oil - risk for overheating.Do not overfill with oil - risk for overheating.
Now repeat the procedure on the opposite side of the
drum.
Fig. Drum
1. Ventilation screw
1
Drum cartridge - Cleaning the ventilation screw
Clean the drum's ventilation hole and ventilation screw
(1). The hole is required to eliminate excess pressure
inside the drum.
Air cleaner
Checking - Change the main air filter
Change the air cleaner's main filter when the
warning lamp on the display lights when the
diesel engine is operating at full speed.
Change the air cleaner's main filter when the
warning lamp on the display lights when the
diesel engine is operating at full speed.
133