Machine description
4812158701_G.pdf 2019-10-01
"CALIBRATION" - service personnel only, requires
password.
"EDC Calibration" used to calibrate the joystick and
speed potentiometer.
"TX Program" only used to change software in the
display and requires special equipment and know-how.
"EDC CALIBRATION"
To calibrate, move the joystick fully forward (F) and
press in both black buttons on the top of the joystick.
(See also manual W3025)
Continue in the same way with the other positions for
the joystick (N), (R) and the speed potentiometer.
Press the disk button to save the values.
Diesel particle filter ("DPF") - (IIIB/T4i)
Shows current "Soot Level" and "Ash Level" in the
DPF filter.
When the "Soot Level" has reached ≥100%, the DPF
filter needs to be burned out.
"ABOUT"
It is also possible to see the version of the installed
software.