Operation
4812158701_G.pdf 2019-10-01
Interlock/Emergency stop/Parking brake -
Check
The interlock, emergency stop and parking brake must
be checked daily before operating. A function check of
the interlock and emergency stop requires a restart.
The interlock, emergency stop and parking brake must
be checked daily before operating. A function check of
the interlock and emergency stop requires a restart.
The interlock function is checked by the operator
standing up from the seat when the roller is moving
very slowly forwards/backwards. (Check in both
directions). Hold the steering wheel firmly and brace
yourself for a sudden stop. A buzzer goes on and after
7 seconds the engine switches off and the brakes are
activated.
The interlock function is checked by the operator
standing up from the seat when the roller is moving
very slowly forwards/backwards. (Check in both
directions). Hold the steering wheel firmly and brace
yourself for a sudden stop. A buzzer goes on and after
7 seconds the engine switches off and the brakes are
activated.
Check the function of the emergency stop by pressing
the emergency stop button.
Check the function of the emergency stop by pressing
the emergency stop button.
Check the function of the parking brake by activating
the parking brake when the roller is moving very
slowly forwards/backwards. (Check in both
directions). Hold the steering wheel and brace yourself
for a sudden stop when the brakes are activated. The
engine does not switch off.
Check the function of the parking brake by activating
the parking brake when the roller is moving very
slowly forwards/backwards. (Check in both
directions). Hold the steering wheel and brace yourself
for a sudden stop when the brakes are activated. The
engine does not switch off.