EasyManua.ls Logo

FEC HFC3000 - Page 46

FEC HFC3000
196 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Installation
PAGE 4-14
NG: FASTENING NG (FAILURE) SIGNAL PIN No.: TB2-1 OUT-1
The “ON” output is performed when an abnormal exit occurs with a fastening result falling outside a
judgment range.
OK: FASTENING OK SIGNAL PIN No.: TB2-2 OUT-2
The “ON” output is performed when normal exit is accomplished with the fastening results being
within the judgment ranges.
ABNORMAL: SYSTEM ERROR/ABNORMAL EXIT PIN No.: TB2-3 OUT-3
The “ON” output is performed when an error is detected during the system check performed by the
controller or during the fastening process.
When an error occurs, fastening is stopped immediately and the fastening results data are stored.
READY: INPUT ENABLING SIGNAL PIN No.: TB2-4 OUT-4
The “ON” output is performed when operation fastening, reverse rotation, etc., can be performed by
an input signal from the PLC or other external equipment.
The READY signal is “OFF” under the following conditions.
During the initialization process in power activation
During reverse rotation
When the ABNORMAL signal is output
In the BYPASS mode (during settings, in the download mode (during communication), etc.)
In the STOP state
During fastening, reset, or CAL check
Other conditions where operation of the controller by an external output is disabled
BUSY: SIGNAL DURING FASTENING PIN No.: TB2-5 OUT-5
The “ON” output is performed when the controller is performing the fastening process.
Fastening Result Data Available PIN No.: TB3-7 OUT-6
The “ON” output is performed when fastening result data are present.
CF CARD FULL PIN No.: TB3-8 OUT-7
The “ON” output is performed when capacity of the CF card is less than 1%, or CF card isnot inserted
BYPASS: BYPASS MODE PIN No.: TB2-6 OUT-12
The “ON” output is performed in the BYPASS mode.
OUTPUT BANK [OFF]

Table of Contents