EasyManua.ls Logo

Feig Electronic TST FU3F-A - Page 84

Feig Electronic TST FU3F-A
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TST Assembly instructions FUF2 / FU3F -A/-C/-F
FEIG ELECTRONIC GmbH page 84 of 114 TST_FUxF-A-C-F_Montageanleitung_EN_15
No.
Description
Possible reason for error
F.166
Motion detector 1
MWD BPC customer coding failed
•customer coding of the MWD BPC is not compatible with the control unit.
•MWD BPC may already be encoded. Replace with an unpaired device
F.168
Motion detector 1
MWD BPC wrong customer coding
•customer coding of the MWD BPC is not compatible with the control unit.
•Replace MWD BPC with unpaired or correctly paired
F.16E
Motion detector 1
MWD BPC software update failed.
• If the error occurs at 0% the update file might be incompatible to the MWD
BPC.
• If the error occurs during the transfer of the update, perform the update
again, if it occurs several times, replace the device
F.170
Motion detector 2
MWD BPC is defective
An exchange of the device is necessary
F.172
Motion detector 2
Communication of the control unit with the MWD BPC
motion detector was interrupted.
•Check the wiring of motion detector 2
•Restart the control unit or the motion detector
F.176
Motion detector 2
MWD BPC customer coding failed
•customer coding of the MWD BPC is not compatible with the control unit.
•MWD BPC may already be encoded. Replace with an unpaired device
F.178
Motion detector 2
MWD BPC wrong customer coding
•customer coding of the MWD BPC is not compatible with the control unit.
•Replace MWD BPC with unpaired or correctly paired
F.17E
Motion detector 2
MWD BPC software update failed.
• If the error occurs at 0% the update file might be incompatible to the MWD
BPC.
• If the error occurs during the transfer of the update, perform the update
again, if it occurs several times, replace the device
F.180
Motion detector 3
MWD BPC is defective
An exchange of the device is necessary
F.182
Motion detector 3
Communication of the control unit with the MWD BPC
motion detector was interrupted.
•Check the wiring of motion detector 3
•Restart the control unit or the motion detector
F.186
Motion detector 3
MWD BPC customer coding failed
•customer coding of the MWD BPC is not compatible with the control unit.
•MWD BPC may already be encoded. Replace with an unpaired device
F.188
Motion detector 3
MWD BPC wrong customer coding
•customer coding of the MWD BPC is not compatible with the control unit.
•Replace MWD BPC with unpaired or correctly paired
F.18E
Motion detector 3
MWD BPC software update failed.
• If the error occurs at 0% the update file might be incompatible to the MWD
BPC.
• If the error occurs during the transfer of the update, perform the update
again, if it occurs several times, replace the device
F.190
Motion detector 4
MWD BPC is defective
An exchange of the device is necessary

Table of Contents