Description of settings
VEK MNH Operating Manual v1.3 en
36 | 56
11.1 Adjusting sensitivity (switch-on threshold)
The switch-on threshold can be selected in 255 increments in the range between 0.01% and 2.55%
f/f. The
higher the switch-on threshold, the lower is the sensitivity for signal activation.
Typical settings
Generally speaking, sensitivity is adjusted in large steps, and the switch-on threshold selected is not
greater than 640.
Switch-on thresholds of over 640 and fine tuning may not be required for differentiation between
vehicles. It is possible to differentiate, for example, buses with large loops (e.g. 10.0 m x 2.5 m) and
correspondingly high threshold values (>1000).
NOTE
Minimising interference factors
In order to minimise interference factors, the sensitivity should be as low as possible, i.e. the value of the
switch-on threshold should be as high as possible.
DIP
(Sense a)
DIP
(Sense b)
Detector Tool
(switch-on
threshold)
Sensitivity (f/f)
ON
ON
10
0.01 % Level high (highest sensitivity)
20
0.02%
30
0.03%
OFF
ON
40
0.04% Level medium-high
50
0.05%
150
0.15%
ON
OFF
160
0.16% Level medium-low
170
0.17%
630
0.63%
OFF
OFF
640
0.64% level medium-low (factory setting)
650
0.65%
1000
1.00%
2550
2.55% Level minimum (lowest sensitivity)
Tab. 17: Sensitivity settings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feig Electronic VEK MNH2-R24-C and is the answer not in the manual?

Feig Electronic VEK MNH2-R24-C Specifications

General IconGeneral
BrandFeig Electronic
ModelVEK MNH2-R24-C
CategorySecurity Sensors
LanguageEnglish

Related product manuals