Description of settings
VEK MNH Operating Manual v1.3 en
39 | 56
11.4 Setting hold time
Separate hold times between 1 and 255 minutes can be set at the detector for each channel. The value 0
corresponds to an infinite hold time. If the loop on a detector channel is covered for longer than the set hold
time, the detector channel runs a frequency alignment. The current detuning of the loop channel is reset.
Limiting the hold time
Limiting the hold time can be used, for example, to remove the vehicle parking on the loop automatically
once the hold time has ended. The loop can then be reused for subsequent vehicles. Permanent activation
caused by faults can also be avoided by setting the hold time appropriately.
DIP (hold time)
Detector Tool
Hold time
ON
0
infinite
1
1 min
OFF
5
5 min
255
255 min
Tab. 21: Hold time settings (VEK MNH)
11.5 Setting output mode (signal type)
Various output modes (signal types) can be set for the outputs.
WARNING
Switching off the direction logic (2 channel version)
The direction logic must be switched off to set the output mode, i.e. Dir. Mode on the DIP switch must be
set to OFF or the direction logic in the Detector Tool must be set to OFF.
DIP (output 2)
Detector Tool
Output signal
OFF
Presence
constant signal (factory setting)
ON
Pulse
Impulse signal
On
output permanently switched on
Off
output permanently switched off
Collective fault
output signal for collective fault
Loop error
output signal for loop error
Tab. 22: Signal type settings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feig Electronic VEK MNH2-R24-C and is the answer not in the manual?

Feig Electronic VEK MNH2-R24-C Specifications

General IconGeneral
BrandFeig Electronic
ModelVEK MNH2-R24-C
CategorySecurity Sensors
LanguageEnglish

Related product manuals