5 |
ECOTRONIC Plus
© Ferroli 08164 ECOTRONIC Plus.monen.indd
De ltaS ol M
Main menu
Meas. values
Reports
Solar
GND
S1
S2
S3
S4
S5
S7
S6
S8
S9
S10
S11
S12
----
CS10
Imp1
Imp2
Bus
VBus
RS232
Sensors
R9-A
R9-M
R9-R
DeltaSol M
LN
R8-A
R8-R
R7-A
R7-R
R6-A
R6-R
R5-A
R5-R
R4-A
R3-A
R2-A
R1-A
floating re la ye lectr omechanic re la y
semi-conductor r ela y
Schutzleiter -Sammelklemmenblock benutzen
Nullleiter -Sammelklemmenblock benutzen
N
Use the PE Collectiv eT erminal Block
Use the Neutral Conductor Collecti ve T erminal Block
N
Masse-Sammelklemmenblock ben utzen
Use the Gr ound Collectiv eT erminal Bloc k
T6,3A
Netz / Mains
220...240 V~
V or Öffnen der Klemmenabdeckung
Gerät spannungslos schalten
Isolate mains befor e re moving clamp-co ve r
6,3 (1) A 220 ... 240 V~
GND
PE
L
N
De ltaS ol M
Main menu
Meas. values
Reports
Solar
GND
S1
S2
S3
S4
S5
S7
S6
S8
S9
S10
S11
S12
----
CS10
Imp1
Imp2
Bus
VBus
RS232
Sensors
R9-A
R9-M
R9-R
DeltaSol M
L N
R8-A
R8-R
R7-A
R7-R
R6-A
R6-R
R5-A
R5-R
R4-A
R3-A
R2-A
R1-A
floating re la y e lectr omechanic re la y
semi-conductor r ela y
Schutzleiter -Sammelklemmenblock benutzen
Nullleiter -Sammelklemmenblock benutzen
N
Use the PE Collectiv eT erminal Block
Use the Neutral Conductor Collecti ve T erminal Block
N
Masse-Sammelklemmenblock ben utzen
Use the Gr ound Collectiv eT erminal Bloc k
T6,3A
Netz / Mains
220...240 V~
V or Öffnen der Klemmenabdeckung
Gerät spannungslos schalten
Isolate mains befor e re moving clamp-co ve r
6,3 (1) A 220 ... 240 V~
GND
PE
L
N
1.2 Electrical connection
VBus
neutral conductor
collective terminal block
mains terminals
fuse T6,3A
(supply to all relays)
sensor terminals
load terminals
sensor ground collective terminal block
RS232
1.2.1 Overview of electrical connections
1.2.2 Sensors
The controller is equipped with 15 sensor inputs in total.
The ground connection for the sensors has to be carried
out via the ground terminal block (GND).
• Temperature sensors have to be connected to the
terminals S1 ... S12 and GND (either polarity).
• Theirradiation sensor (CS10) is to be connected
to the terminals CS10 and GND with correct polarity.
Connect the terminal GND of the sensor to the terminal
GND of the controller (ground terminal block), and the
terminal CS of the sensor to the terminal CS10 of the
controller.
• Twoflowmeters V40 can be connected to the terminals
lmp1... lmp2 and GND (either polarity).
• Theoptional,heatingcircuit,remotecontrolRTA11-M
should be connected to terminals S10 (factory setting)
and GND (either polarity).
Netz / Mains
220 ... 240 V~
protective conductor
collective terminal block